Assignment 1:-

Develop a ladder logic for a FLASHER (10 second duration) such that, when Switch is turned ON,

The FLASHER should glow for 10 second duration.

The FLASHER should not glow for 10 second duration.

The FLASHER then continues.

Assignment 2:-

Develop a ladder logic for a FLASHER (10 second duration) such that, when Switch is turned ON,

The FLASHER should not glow for 10 second duration.

The FLASHER should glow for 10 second duration.

The FLASHER then continues.

Assignment 3:-

Develop a ladder logic for FLASHER such that, when Switch is turned ON,

The FLASHER should glows for 15 second duration.

The FLASHER should not glow for 10 second duration.

The FLASHER then continues.

Assignment 4:-

Develop a ladder logic for FLASHER such that,

The FLASHER should not glow for 5 second duration.

The FLASHER should glows for 15 second duration.

The FLASHER runs for 30 second and then stops.

Assignment 5:-

Develop a ladder logic for FLASHER such that,

The FLASHER should glows for 10 second duration.

The FLASHER should not glow for 5 second duration.

The FLASHER runs for 1 minute and then stops.

Assignment 6:-

Develop a ladder logic for FLASHER such that,

The FLASHER should glows for 5 second duration.

The FLASHER should not glow for 10 second duration.

The FLASHER runs for 10 second.

Then FLASHER stops for 15 second.

Then FLASHER runs for 2 minutes then stops.

Assignments 7:-

Three pumps are to be monitored. If all 3 pumps are running, one digital output should glow steadily, if any two pumps are running the output should flash slowly and if only one pump is running then the output flashes at a faster rate. (Only one digital output).

Assignments 8:-

Program an alarm system such that the following logic is operated for the four inputs:

1) If only one of any inputs is on, one yellow lamp turns on for 20 seconds.

2) If 2 inputs are turned on, a red light turns on after 5 seconds.

3) If 3 inputs are turned on, an alarm is fired.

4) If all 4 inputs are turned on, the alarm is fires and the Fir station is called.

5) With one push button the system is reset.

Useful Links:-

Recent Posts

Popular Posts

Wonderware Intouch Cracked

Wonderware IntouchInTouch software leaps onto your screen with breakthrough technology, amazing graphic capabilities, and comprehensive functionality delivered with Wonderware’s legendary ease of use. Wonderware’s...

How to Install Intouch License: Download, Types, Features, Working

Intouch LicenseWonderware is a powerful and widely-used software platform that is used by many businesses and organizations to streamline their operations and increase efficiency....

Visual Basic and C-Action Script WinCC: How to Write Script

Action ScriptsActionScript is a programming language used to create interactive and dynamic animations, games, and applications for the web and mobile devices. It is...

Popular Softwares

Wonderware Intouch Cracked

Wonderware IntouchInTouch software leaps onto your screen with breakthrough technology, amazing graphic capabilities, and comprehensive functionality delivered with Wonderware’s legendary ease of use. Wonderware’s...

Download RSLogix 500 v12

RSLogix 500 is a programming software developed by Rockwell Automation for programming and configuring Allen-Bradley PLCs (Programmable Logic Controllers). It is part of the...

GX Developer free download

GX Developer with serial keyGX-Developer is a software program used for programming and controlling programmable logic controllers (PLCs) made by Mitsubishi Electric. It is...

FIND MORE